MODEL
|
HDC-35A
|
HDC-35B
|
|
OUTPUT
|
OUTPUT
|
CH1 |
CH2
|
CH1
|
CH2
|
|
DC Voltage
|
5V
|
12V
|
5V
|
24V
|
|
Rated Current
|
4A
|
1A
|
2.2A
|
1A
|
|
Current Range
|
0.5-5A
|
0.1-1.5A
|
0.5-4A
|
0.2-1.3A
|
|
Rated Power
|
32W
|
35W
|
|
Ripple & Noise
|
80mVp-p
|
120mVp-p
|
80mVp-p
|
200mVp-p
|
|
DC Adjustment Range
|
CH1:4.75-5.5V
|
CH1:4.75-5.5V
|
|
Voltage Tolerance
|
±2.0%
|
±6.0%
|
±2.0%
|
±6.0%
|
|
Line Regulation
|
±0.5%
|
±1.0%
|
±0.5%
|
±1.0%
|
|
Load Stability
|
±1.5%
|
±3.0%
|
±1.5%
|
±3.0%
|
|
Setup, Rise, Hold Time
|
500ms、30ms/230VAC 1200ms、30ms/115VAC
50ms/230VAC, 10ms/115VAC
|
|
INPUT
|
Voltage Range
|
AC 85~264VAC DC120~370VDC
|
|
Frequency
|
47-63Hz
|
|
Efficiency
|
78%
|
81% |
|
AC Current
|
0.75A/ 115V 0.5A/230V
|
|
Inrush Current
|
Cold start 45A/230VAC
|
|
Leakage Current
|
< 2mA/240VAC
|
|
PROTECTION
|
Over Load
|
110%~150% Protection: Hiccup mode,recovers automatically after fault condition is removed
|
|
Over voltage
|
CH1:5.75-6.75 Protection type: Shut down o/p voltage, re-power on to recover
|
|
ENVIRONMENT
|
Working Temp., Humidity
|
-20℃~+60℃;20%~90 %RH no cooling(Refer to output load derating curve)
|
|
Storage Temp., Humidity
|
-40℃~+85℃;10%~95 %RH
|
|
Vibration
|
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes
|
|
SAFETY
|
Withstand Voltage
|
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
|
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
|
|
STANDARD
|
Safety Standard
|
Design refer to UL60950-1,CB(IEC60950-1)
|
|
EMC Standard
|
Design refer to EN55022 CLASSB EN61000-3-2,-3 EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-1
|
|
OTHERS
|
Weight
|
0.36Kg
|
|
Packing
|
45pcs/17Kg/0.99CUFT
|
|
NOTE
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.Each output can reach to maxium current, but the total load can not exceed rated power.
5.The power supply is considered as a component inside the equipment, the final equipment must be confirmed it meets EMC directives.
|