HPS-65 Single Output Switching Power Supply
Features
- High efficiency, high reliability
- Universal AC input/ full range
- Low leakage current <0.5mA
- 100% full load burn-in test
- Protections: Short circuit/ Over load/ Over voltage
- Cooling by free air convection
- Fixed switching frequency at 65KHz
- 1 year warranty
- Dimensions: 127*76.2*42mm (L*W*H)
| MODEL |
HPS-65-3.3 |
HPS-65-5 |
HPS-65-7.5 |
HPS-65-12 |
HPS-65-13.5 |
HPS-65-15 |
HPS-65-24 |
HPS-65-27 |
HPS-65-48 |
| OUTPUT |
DC Voltage |
3.3V |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
| Voltage Tolerance |
±3.0% |
±3.0% |
±3.0% |
±2% |
±2% |
±2% |
±2% |
±2% |
±2% |
| Rated Current |
12A |
12A |
8A |
5.2A |
4.7A |
4.2A |
2.7A |
2.4A |
1.3A |
| Current Range |
0-15.2A |
0-13.8A |
0-9.6A |
0-6A |
0-5.4A |
0-4.8A |
0-3A |
0-2.7A |
0-1.5A |
| Rated Power |
39.6W |
60W |
60W |
62.4W |
63.5W |
63W |
64.8W |
64.8W |
64.8W |
| Ripple & Noise |
80mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
100mVp-p |
| DC Adjustment Range |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
-5%, +10% |
| Setup, Rise, Hold Time |
800ms, 20ms, 60ms at full load |
| INPUT |
Voltage Range |
90~264VAC47~440Hz ,127~370VDC |
| AC Current |
1.2A/115VAC0.72A/230VAC |
| Efficiency |
69% |
76% |
79% |
79% |
79% |
79% |
80% |
80% |
80% |
| Inrush Current |
Cold start 20A/115VAC40A/230VAC |
| Leakage Current |
<0.5 mA/240VAC |
| PROTECTION |
Over Load |
53-75W(3.3V:36-55W)Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage |
115%~135%Hiccup mode, recovers automatically after fault condition is removed |
| ENVIRONMENT |
Working Temp., Humidity |
-10℃~+60℃; 20%~90 %RH |
| Storage Temp., Humidity |
-20℃~+85℃; 10%~95 %RH |
| Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
| STANDARD |
Safety Standard |
Design refer to UL60950, TUV EN60950-1 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
| OTHERS |
Weight |
0.21Kg |
| Packing |
54pcs/14.2Kg / 1.35CUFT |
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes. |
Outline and dimension
| Output derating |
Output derating VS Input voltage |
 |
 |
|