Settlement for installation place(Installation of safety light curtains)

For personnel security assurance, the installation place of safety light curtain should conform to distance and height requirements. Calculation of safe distance: Safe distance refers to the request minimum distance from screen plane of safety light curtain to dangerous equipments part.

For the machine or equipment, machine slider or dangerous parts can have the auto-stop anywhere of the run. Safety formula: Ds=K (T+C)
- K: the operator’s hands extension speed, generally count in 1600mm/s
- T1: response time of safety light curtain, about 0.02s
- T2: Maximum braking stop time, that is the time from braking start to slider or dangerous stop, unit in S

For the machine or equipment, machine slider or dangerous parts can not have the auto-stop anywhere of the run Safety formula: Ds=KT T=(1/2 +1/N)Tn
- K: the operator’s hands extension speed, generally count in 1600mm/s
- T: slider or dangerous parts trip down to the dead point, unit in S
- N: joint slots number of clutch
- Tn: a lap rotation time for crankshaft, unit in S

Calculation of safe height(Installation of safety light curtains)

Height position refers to screen relative to up and down position of machine dangerous parts. That is on the basis of safe assurance, the undermost beam should not be higher than lower limb of dangerous part, and the topmost beam should not be lower than upper limb of dangerous part. Protection height≥ dangerous part trip+regulating variable

Schematic diagram of the correct installation

Schematic diagram of the correct installation     Schematic diagram of the correct installation

Main installation way(Installation)

The installation ways include: normal upper and bottom shock absorber type, T-slot side installation, tubular installation, floor installation, shield installation
 

-

-

-

-
-
Normal upper and bottom shock absorber type is the main installation, which is easy and reliable, can increase shock absorber by KS fixture bracket to reduce vibration effectively.
T-slot side installation is easy and practical, can fix the safety light curtain on the device column by two pieces right angle bending board, the disadvantage is hard adjustment, poor anti-vibration, applicable to set in smooth places.
Tubular bracket with shock absorber, tubular connect with safety light curtain by shock absorber, can reduce vibration effectively. Mainly use in the larger vibration equipment such as punch and press.
Floor bracket installation generally use for dangerous area protection or equipment working area safety protection.
Shield installation use in the equipment that the safety light curtain is easy to bump.



Normal frontal shock absorber installation

Directly connect receiver and emitter on the equipment by KS type normal frontal bracket, generally use in fame structure equipments.

Normal frontal shock absorber installation     Normal frontal shock absorber installation

Normal side installation

Receiver and Emitter are fixed on the equipment by T-nut and L-bending bracket. Generally use in fame
structure equipments.

Normal side installation     Normal side installation

Tubular bracket installation

Receiver and Emitter are fixed on the adjustable tubular bracket by KS-tube clamp. Cantilevered base is fixed on the machine bottom base or upright post. Generally use in machine, punch and press.

Tubular bracket installation     Tubular bracket installation

Floor bracket installation

Receiver and Emitter are fixed on the adjustable tubular bracket by KS-tube clamp. Floor bracket base is fixed on the protection floor. Generally use for area protection. It can be to minimize the vibration.

Floor bracket installation     Floor bracket installation

Shield installation

It can increase shield then the safety light curtain is easy to be bumped so as to protect receiver and emitter.

Shield installation    

Installation assembly

 

Optical axis Optical axis distance 20mm Optical axis distance 40mm
number H J L C H J L C
4 60 160 500 220 120 240 500 300
6 100 200 500 260 200 320 500 380
8 140 240 500 300 280 400 750 460
10 180 280 500 340 360 480 750 540
12 220 320 750 380 440 560 1000 620
14 260 360 750 420 520 640 1000 700
16 300 400 750 460 600 720 1000 780
18 340 440 750 500 680 800 1000 860
20 380 480 750 540 760 880 1200 940
22 420 520 750 580 840 960 1200 1020
24 460 560 1000 620 920 1040 1500 1100
26 500 600 1000 660 1000 1120 1500 1180
28 540 640 1000 700 1080 1200 1500 1260
30 580 680 1000 740 1160 1280 1500 1340
32 620 720 1000 780 1240 1360 1750 1420
34 660 760 1000 820 1320 1440 1750 1500
36 700 800 1000 860 1400 1520 1750 1580
38 740 840 1200 900 1480 1600 2000 1660
40 780 880 1200 940 1560 1680 2000 1740



 

Optical axis Optical axis distance 10mm
number H J L C
8 70 160 500 220
16 150 240 500 300
24 230 320 750 380
32 310 400 750 460
40 390 480 750 540
48 470 560 1000 620
56 550 640 1000 700
64 630 720 1000 780
72 710 800 1000 860



 

Optical axis Optical axis distance 80mm
number H J L C
4 240 400 750 460
8 560 720 1000 780
12 880 1040 1500 1100
16 1200 1360 1750 1420
20 1520 1680 2000 1740



 

KS type normal frontal bracket L type bending board Shield tubular bracket
KS type normal frontal bracket L type bending board Shield tubular bracket
Tubular fix bracket GA light curtain shock absorber GAD, GE light curtain shock absorber
Tubular fix bracket GA light curtain shock absorber GAD, GE light curtain shock absorber
Tubular bracket with rotation arm Tubular bracket with rotation arm base
Tubular bracket with rotation arm Tubular bracket with rotation arm base
Emitter/receiver Reflection mirror Bracket steel pipe
Emitter/receiver Reflection mirror Bracket steel pipe
Shield Floor bracket steel pipe base
Shield Floor bracket steel pipe base
 

If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day.

Product*
E-mail *
For example : Peter@greegoo.com
Message*
Your Name*
For example : Peter Xiao. First name and Last name
Company
For example : Greegoo Electric Co.,Ltd
Telephone*
For example : 0086-577-62776000(Country code + City code + Tel numbers)
  
 

Related Products: