GD-100 Dual Output Switching Power Supply
Features
- High efficiency,high reliability
- AC input range selected by switch
- 100% full load burn-in test
- Protection: Short circuit/Over load
- Cooling by free air convection
- Fixed switching frequency at 25KHz
- 1 year warranty
- Dimensions: 199*98*38mm(L*W*H)
| MODEL |
GD-100A |
GD-100B |
GD-100C |
| CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
| OUTPUT |
DC Voltage
|
5V |
12V |
5V |
24V |
12V |
24V |
|
Voltage Tolerance
|
±2% |
±6% |
±2% |
±7% |
±2% |
±7% |
|
Rated Current
|
15A |
2A |
15A |
1A |
4A |
2A |
|
Current Range
|
1-15A |
0.3-2A |
1-15A |
0.2-1A |
0.2-2A |
0.2-2A |
|
Rated Power
|
99W |
99W |
96W |
|
Ripple & Noise
|
100mVp-p |
120mVp-p |
100mVp-p |
100mVp-p |
150mVp-p |
150mVp-p |
|
DC Adjustment Range
|
CH1:-5%,+10%
|
|
Setup, Rise, Hold Time
|
200ms,50ms,20ms at full load
|
| INPUT |
Voltage Range
|
85~132 VAC / 180~264VAC 47~63 Hz; Selected by switch 255~370VDC
|
|
AC Current
|
2.4A/115 V 1.2A/ 230 V
|
|
Efficiency
|
73%
|
|
Inrush Current
|
Cold start 30A/115V 60A/230V
|
|
Leakage Current
|
<1mA/240VAC
|
| PROTECTION |
Over Load
|
105%~165%
|
|
Protection: Shut down o/p voltage, re-power on to recover
|
| ENVIRONMENT |
Working Temp., Humidity
|
-10℃~+50℃;20%~90 %RH
|
|
Storage Temp., Humidity
|
-20℃~+85℃;10%~95 %RH
|
|
Vibration
|
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes
|
| SAFETY |
Withstand Voltage
|
I/P-O/P:1.5KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
|
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC
|
| STANDARD |
Safety Standard
|
Design refer to UL1012
|
| OTHERS |
Weight
|
0.62Kg
|
|
Packing
|
30pcs/19Kg/0.99CUFT
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
|
|