HS-150R Single Output Switching Power Supply
Features
- Protections:Short circuit/Over load/Over voltage
- Forced air cooling by built in DC fan
- Built-in cooling Fan ON-OFF control
- Built in LED indicator for power on
- 100% full load burn-in test
- Fixed switching frequency at 65KHZ
- High efficiency,long life,high reliability,water proof
- 1 year warranty
- Dimensions: 194*127*107mm (L*W*H)
|
MODEL
|
HS-150R-5
|
HS-150R-12
|
HS-150R-15
|
HS-150R-24
|
|
OUTPUT
|
DC Voltage
|
5V
|
12V
|
15V
|
24V
|
|
Voltage Tolerance
|
±1.0%
|
±1.0%
|
±1.0%
|
±1.0%
|
|
Rated Current
|
25A
|
12.5A
|
10A
|
6.3A
|
|
Current Range
|
0-25A
|
0-12.5A
|
0-10A
|
0-6.3A
|
|
Line Regulation
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Load Stability
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
|
Rated Power
|
125W
|
150W
|
150W
|
151.2W
|
|
Ripple & Noise
|
100mVp-p
|
120mVp-p
|
120mVp-p
|
120mVp-p
|
|
DC Adjustment Range
|
4.75-5.5V
|
10.8-13.2V
|
13.5-16.5V
|
21.6-26.4V
|
|
Setup, Rise, Hold Time
|
800ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
|
|
Hold Time
|
28ms/230VAC 20ms/115VAC at full load
|
|
INPUT
|
Voltage Range
|
90~132VAC /180~264 selected by switch, 248~373VDC
|
|
AC Current
|
3A/115VAC 2A/230VAC
|
|
Frequency
|
47~63Hz
|
|
Efficiency
|
80%
|
83%
|
84%
|
86%
|
|
AC Current
|
3A/115VAC 2A/230VAC
|
|
Inrush Current
|
Cold start 40A/230VAC
|
|
Leakage Current
|
<2mA / 240VAC
|
|
PROTECTION
|
Over Load
|
110~150%
|
|
Protection: Hiccup mode, recovers automatically after fault condition is removed
|
|
Over Voltage(V)
|
5.75~6.75V
|
13.8~16.2V
|
17.25~20.25V
|
27.6~32.4V
|
|
Protection: Hiccup mode, recovers automatically after fault condition is removed
|
|
ENVIRONMENT
|
Working Temp., Humidity
|
-10~+70℃, 20~90% RH
|
|
Storage Temp., Humidity
|
-20~+85℃ , 10~95% RH
|
|
Vibration
|
10~500Hz, 2G 10min./1 cycle,period for 60 min. Each along X,Y, Z axes
|
|
SAFETY
|
Withstand Voltage
|
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC
|
|
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
|
|
STANDARD
|
Safety Standard
|
Design refer to UL1012, EN60950
|
|
EMC Standard
|
Design refer to EN55022 CLASSA
|
|
OTHERS
|
Weight
|
|
|
Packing
|
|
|
NOTE
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
|
Outline and installation dimension
| Derating curve |
Static characteristis |
 |
 |
|