| Industrial DIN Rail Power Supply(240W Single Output) |
|---|
| - Universal AC input/ full range - Built-in active PFC function - Protections: Short circuit/ Over load/ Over voltage/Over temperature - Cooling by free air convection - Can be installed on DIN rail TS-35/7.5 or 15 - LED indicator for power on - 100% full load burn-in test - Fixed switching frequency at 100KHz - 3 years warranty - Dimentsions: 125.5*125.2*100mm (W*H*D) |
| Model | HDR-240-24 | HDR-240-48 | |
| Output | DC Voltage | 24V | 48V |
| Voltage Tolerance | +1% | +1% | |
| Rated Current | 10A | 5A | |
| Current Range | 0-10A | 0-5A | |
| Rated Power | 240W | 240W | |
| Ripple & Noise | 80mVp-p | 150mVp-p | |
| DC Adjustment Range | 24-48V | 48-53V | |
| Setup, Rise, Hold Time | 800ms,40ms/230VAC at full load800ms,40ms/115VA Cat full load | ||
| Hold Time | 24ms/230VAC24ms/115VAC at full load | ||
| Input | Voltage Range | 88~264VAC47~63 Hz; selected by switch 120~370VDC | |
| AC Current | 2.8A/115 V 1.4A/ 230V | ||
| Efficiency | 84% | 85% | |
| Inrush Current | Cold start 27A/115V 45A/230V | ||
| Leakage Current | <3.5mA/240VAC | ||
| Protection | Over Load | 105%~150% | |
| Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||
| Over Voltage | 30-36V | 54-60V | |
| Protection type: Shut down o/p voltage, re-power on to recover | |||
| OVER TEMP. | 100℃+5℃ | ||
| Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | |||
| Environment | Working Temp & Humidity | -10℃~+70℃;20%~90 %RH | |
| Storage Temp &Humidity | -20℃~+85℃;10%~95 %RH | ||
| Vibration | 10~500Hz,2G 10min./1cycle, period for 60min,each along X, Y, Z axes | ||
| Safety | Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | |
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC | ||
| Standards | Safety Standard | Design refer to UL508,UL60950-1,TUV EN60950-1 | |
| EMC Standard | Design refer to EN55011,EN55022,EN61000-3-2,-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204,EN55024,EN61000-6-2 | ||
| Others | Weight | 1.2Kg | |
| Packing | 12pcs/15.5Kg/1.2CUFT | ||