Catalog

Featured Products

Product's News

Contact Information
| GDR-60 |


| Bookmark This Page | ||||||
| Print This Page | ||||||
| Live Messenger | ||||||
| Skype Me | ||||||
| Peter@greegoo.com | ||||||
| Catalogue Download | ||||||
| Add to Inquiry Basket | View Inquiry Basket | ||||||
Industrial DIN Rail Power Supply (60W Single Output GDR-60)
Feature
| - Universal AC input/Full range - Protections: Short circuit / Overload /Over voltage - Cooling by free air convection - Can be installed on DIN rail TS-35/7.5 or 15 - NEC class 2 / LPS compliant - Built in DC OK active signal - LED indicator for power on - No load power consumption<0.75W - 100% full load burn-in test - 3 years warranty |
| Model | GDR-60-5 | GDR-60-12 | GDR-60-24 | GDR-60-48 | |
| Output | DC Voltage | 5V | 12V | 24V | 48V |
| Rated Current | 10A | 5A | 2.5A | 1.25A | |
| Current Range | 0-10A | 0-5A | 0-2.5A | 0-1.25A | |
| Rated Power | 50W | 60W | 60W | 60W | |
| Ripple & Noise | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
| DC Voltage Adj.Range | 5-6V | 12-15V | 24-30V | 48-56V | |
| Voltage Tolerance | +2.0% | +1.0% | +1.0% | +1.0% | |
| Line Regulation | +1.0% | +1.0% | +1.0% | +1.0% | |
| Load Regulation | +1.0% | +1.0% | +1.0% | +1.0% | |
| Setup, Rise Time | 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load | ||||
| Hold Up Time (Typ.) | 50ms/230VAC 120-370VDC | ||||
| Input | Voltage Range | 85-264VAC 120-370VDC | |||
| Frequency range | 47-63Hz | ||||
| Efficiency | 78% | 86% | 88% | 87% | |
| AC Current(Typ.) | 1.8A/115VAC 1A/230VAC | ||||
| Inrush current(Typ.) | Cold start 30A/115VAC 60A/230VAC | ||||
| Leakage current | <1mA/240VAC | ||||
| Protection | Over Load | 105%~150% rated output power Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||
| Over Voltage | 6.25-7.25V | 15.6-18V | 31.2-36V | 57.6-64.8V | |
| Protection type: shut down o/p voltage, re-power on to recover | |||||
| Function | DC OK AC tive signal | Relay contact rating(max.):30V/1A resistive | |||
| Environment | Working temp. | -20-+70℃ (Refer to output load derating curve) | |||
| Working humidity | 20℃~90℃, RH non-condensing | ||||
| Storage Temp & Humidity | -40℃~+85℃, 10%~95 %RH | ||||
| Temp. coefficient | +0.03%/℃(0-50℃) | ||||
| Vibration | Component:10-500Hz, 2G 10min./1cycle, 60min, each along X,Y,Z axes;Mounting:Compliance to IEC60068 | ||||
| Safety & EMC | Safety standards | UL508, TUV EN60950-1 approved, NEC class 2 / LPS compliant(24V, 48V only) | |||
| Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
| Is olation resistance | I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25℃ 70%RH | ||||
| EMI conduction | Compliance to EN55011,EN55022 (CISPR22), EN61204-3 Class B | ||||
| Harmonic current | Compliance to EN61000-3-2,-3 | ||||
| EMS immunity | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
||||
| Others | Dimension Mibf | 299.2k hrs min, MIL-HDBK-217F(25˚C) | |||
| Dimension | 40x90x100mm(WxHxD) | ||||
| Packing | 0.3kg; 40pcs/12kg/0.03cbm | ||||
Outline and dimension
Mechanical Specification

Block Diagram

Derating Curve Output Derating VS Input Voltage

DC OK Relay Contact
| Contact.Close | When.the.output.voltage.reaches.the.adjusted.output.voltage. |
| Contact.Open | When.the.output.voltage.drop.below.90%.output.voltage. |
| Contact.Ratings.(max.) | 30V/1A resistive.load |
Notes:
| - - - - - |
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |
If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day. |
Related Products: